Product Details

Place of Origin: Shenzhen, China

Brand Name: Flo-Instru

Certification: ISO:9001, CE

Model Number: FL101

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Conventional Packaging

Delivery Time: 3-5 working days

Payment Terms: T/T

Get Best Price
Highlight:

±1.0% Accuracy Ultrasonic Flow Meter

,

24V DC Power Supply In-Line Flow Meter

,

RS485 Communication FL101 Flow Meter

Accuracy:
±1.0%
Pipe Material:
UPVC
Display:
1.54’’ 240*240 IPS LCD 360° Rotation
Power Supply:
24V DC
Communication Interface:
RS485, Support Modbus RTU Protocol
Flow Range:
0.1m/s ~ 10m/s
Accuracy:
±1.0%
Pipe Material:
UPVC
Display:
1.54’’ 240*240 IPS LCD 360° Rotation
Power Supply:
24V DC
Communication Interface:
RS485, Support Modbus RTU Protocol
Flow Range:
0.1m/s ~ 10m/s
FL101 In-Line Ultrasonic Flow Meter with ±1.0% Accuracy, 24V DC Power Supply, and RS485 Communication
Clamp-on Ultrasonic Flowmeter FL101 In Line Flow Meter Offering Digital and Analog Outputs for Production Process Monitoring
FL101 In-Line Ultrasonic Flow Meter

FL101 is specially designed for measuring the flow of various liquids in pipelines, enabling real-time flow measurement in production processes. The instrument outputs digital signals, analog signals, and more to facilitate measurement and control of production processes.

With industrial upgrading requirements, instruments need rich outputs to achieve automation. Traditional flow meters often have limited outputs that cannot meet on-site needs and require replacement in original positions. Flo-Instruments has introduced an in-line flow meter with full straight pipe design without pressure loss, double union connection, and simple installation.

Key Benefits
Advanced Measurement Technology

Built-in advanced measurement chip with time resolution up to 20ps

  • Four-line OLED display
  • Date/signal/instantaneous/accumulated data
  • Clear visibility in low light and dim environments
FL101 flow meter display showing four-line OLED screen
User-Friendly Interface
  • Innovative menu method (drop-down list)
  • Four-touch buttons for easy setup
  • Simplified/Traditional/English language switching
Robust Construction
  • IP66 protection rating
  • Injection molding structure
  • Double union connection for easy and reliable installation
Product Dimensions
FL101 flow meter dimensional diagram FL101 flow meter dimensional specifications
Model Nominal Pipe Diameter L A B C D
PVC-U-20 DN15 146 182 53.5 93.7 20
PVC-U-25 DN20 149 189 57.3 98.2 25
PVC-U-32 DN25 157 205 70 108 32
PVC-U-40 DN32 157 211 83 118.5 40

Unit: mm

Note: "L" is the length of the pipe section cut off during installation; "D" is the outer diameter of the installed pipe section.

Compatible Media

Since its market introduction, this product has been widely used in the cleaning equipment industry. Due to its simple installation, operation, and reliable measurement performance, it has been continuously promoted in new industries.

Main industries: semiconductors, food, medicine, drinking water, detergents, printing and dyeing, chemical products, etc.

FL101 flow meter measuring various media
Measured Media Examples
  • Dilute sulfuric acid
  • Liquor
  • Hydrocarbon
  • Alcohol
  • Sodium chloride
  • Sodium carbonate
  • Triethylamine
  • Ethylenediamine
  • Propylene oxide etc.
Media Measurement Criteria
  • The flow rate of the medium in the pipeline is stable
  • The pressure is maintained at 0.3MPa
  • No bubbles (cavitation) will be generated due to flow

As the market expands, we continue to discover more measurable media. We encourage users to share additional applications to help us continuously enrich and improve our products.

Many more media have been measured - welcome to consult for specific applications.

FL101 flow meter technical applications
Technical Specifications
Product Name FL101 In-line Ultrasonic Flow Meter
Accuracy ±1.0% (0.3m/s~5.0m/s)
Flow Velocity 0.1m/s~10.0m/s
Linearity ±1.0% (0.3m/s-5.0m/s)
Repeatability 0.40%
Response Time 500ms
Screen Display 1.54'' 240*240 IPS LCD 360° rotation (for easy reading)
Menu Language Simplified Chinese/Traditional Chinese/English
Display Unit Supports metric and imperial unit selection, m³/h, LPM, ml/min, GPM, LPH, factory default unit is LPM
Display Data Instantaneous flow, instantaneous flow velocity, net cumulative volume, single cumulative volume, daily max value, daily min value, daily/monthly/annual cumulative volume
Totalizer 7-digit flow totalizer
Cumulative Data 10 years 64 months 64 days
Operation Key Four touch buttons
Calendar Battery CR1220
Power Supply 24VDC@3W
Analog Output 4-20mA, maximum load 600Ω
Communication Interface RS485, support ModBus RTU protocol
Alarm Output OCT upper and lower limit alarm output, pulse output, etc.
Relay Output (Optional) 30VDC@1A, switching frequency less than 2Hz
Media Water, solutions, chemical reagents (impurities ≤ 4%), etc.
Protection Level IP66
Installation Method The pipe sections are integrated, and the PVC-U pipes are connected by unions (slip joints)
Pipe Size OD20 (DN15-½"), OD25 (DN20-¾"), OD32 (DN25-1"), OD40 (DN32-1½")
Pipe Section Material UPVC
Media Temperature 0°C-60°
Working Temperature -10°C-50°C
Ambient Humidity Relative humidity 0%-95%, no condensation
Applicable Viscosity <300CST (mm²/s)
Cable Length Standard: 2m(6.6ft). It can be lengthened to 20m(66ft)
Installation Guide
Step 1: Cutting the pipe for FL101 installation
1. Cutting the pipe

According to the installation point selection requirements, cut a section of the pipe at the installation location.

Step 2: Inserting nuts into the pipe for FL101 installation
2. Insert the nuts into the pipe

Unscrew the two nuts from the meter and insert them into the pipe.

Step 3: Gluing pipe joints for FL101 installation
3. Glue the pipe joints

Apply PVC glue to the two pipe joints on the instrument and plug them into the pipes.

Step 4: Installing FL101 flow meter
4. Install the flow meter

Place the meter in the middle and tighten the nut to complete the installation; pay attention to the flow direction during installation.

Step 5: Powering on FL101 flow meter
5. Power on and run

Connect the other end of the cable to a 24V DC power supply, power on and observe.

Package & Accessories
FL101 flow meter package contents and accessories
Ordering Information
FL101 Code Pipe Size Range [DN & Inch & OD]
A DN15 | 1/2" | OD20
B DN20 | 3/4" | OD25
C DN25 | 1" | OD32
D DN32 | 1-1/4" | OD40
Code Output Mode
1 4-20mA, RS485, OCT Pulse, Relay
Code Cable Length
L 6.6ft(2m) (If no choice, it will be defaulted)
L+ on request other lengths
Complete Ordering Format

FL101 | A | 1 | L

Example: FL101 with DN15 pipe size, standard outputs, and 2m cable length