Product Details

Place of Origin: Shenzhen

Brand Name: Flo-Instru

Certification: CE; ISO9001

Model Number: ST502

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Conventional Packaging

Delivery Time: 3-5 working days

Payment Terms: T/T

Get Best Price
Highlight:

ST502 ultrasonic water treatment system

,

water treatment system with flowmeter

,

transit time flow monitoring system

Pipe Size:
DN25-DN5000
Liquid:
Water, Sea Water, Oil, Alcohol...
Pipe Material:
PVC, Carbon Steel, Stainless Steel...
Velocity Range:
0.03 ~±40ft/s (0.01~±12m/s)
Repeatability:
0.15%
Power Supply:
24V DC
Transducers:
Operating Temperature: -40℉ ~ +140℉ (-40℃~+60℃)
Display:
20*2, Alphanumeric, Backlit LCD
Output:
4-20mA, OCT Pulse Output, Relay Output, RS-232 / RS-485, RTD Temp. Input
Transmitter Enclosure:
IP65, Die-cast Aluminum Machined Enclosure, CNC Machined
Linearity:
1.0%
Communication:
RS485
Keypad:
16 Light Tactile Keys
Pipe Size:
DN25-DN5000
Liquid:
Water, Sea Water, Oil, Alcohol...
Pipe Material:
PVC, Carbon Steel, Stainless Steel...
Velocity Range:
0.03 ~±40ft/s (0.01~±12m/s)
Repeatability:
0.15%
Power Supply:
24V DC
Transducers:
Operating Temperature: -40℉ ~ +140℉ (-40℃~+60℃)
Display:
20*2, Alphanumeric, Backlit LCD
Output:
4-20mA, OCT Pulse Output, Relay Output, RS-232 / RS-485, RTD Temp. Input
Transmitter Enclosure:
IP65, Die-cast Aluminum Machined Enclosure, CNC Machined
Linearity:
1.0%
Communication:
RS485
Keypad:
16 Light Tactile Keys
ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring

ST502 Clamp-on Ultrasonic Flowmeter

Ultrasonic flow meters that use transit-time methods to measure flow.


Introduction

ST502 Ultrasonic flow meter uses the most reliable digital signal processing technology, transmitting flow measurement for a wide range of liquid and pipe size with high accuracy and reliability. Combined the outstanding performance transducer with higher industrial level material, Flo-Instruments can have long time work without any worries.

Clear menu display selections make use of instruments very convenient. Clamp-on transducers makes the unit more flexible over a wide range of applications.

The ST502 ultrasonic flowmeter is based on Transit-Time technology, which has high measurement accuracy. ST502 uses a clamp-on transducer, which can collect flow data simply by clamping it on the outside of the pipe, and it will never come into contact with the fluid, and will not cause liquid pollution, pressure reduction, leakage, etc.


Benefits

    • Measures the actual flow and total consumption of various liquids
    • CNC machined process, magnetic open cover technology without any screws.
    • Adaptive signal processing algorithms optimize performance, ensuring accurate measurements even in challenging flow conditions
    • Clear display interface and LCD display with alarm function, easy to operate and debug
    • Utilize transit-time ultrasonic technology so as to realize bidirectional flow measurement by precisely measuring the time it takes for ultrasonic signals to transmit upstream and downstream
    • Built-in 2G SD card and leverage storage capabilities to analyze historical flow data to make system optimization.
    • Built-in keypad and simple menu system for fast and easy option of pipe diameter, pipe material, liquid type, and measurement units.


ST502 is a brand-new high-end product that is made of aluminum alloy material and realizes CNC processing method. It adopts the industry-leading full-sealed iron-absorbing side-opening technology without any screw locking, and the tedious steps of screwing are reduced. Such a convenient design truly realizes "one-second opening".



Principle

  • Introduction to TVT

TVT(Transit-Time Vortex) technology represents a cutting-edge approach to ultrasonic flow measurement, combining the principles of transit-time ultrasonics with the capability to harness the vortex shedding phenomenon, delivering unparalleled accuracy and versatility in ultrasonic flow meters. This innovative integration technology enhances the accuracy, versatility, and performance of ultrasonic flow meters, making them well-suited for a wide range of applications across various industries and is a valuable solution for industries requiring precise flow measurements in varying flow conditions.

ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 0

The device has a pair (or more) of ultrasonic transducers installed on the exterior of the pipe (clamp-on) or inserted in-line. One transducer sends an ultrasonic pulse downstream with the flow, while the other sends it upstream, against the flow. Since the fluid's movement affects the transit time of the ultrasound, the time difference between the two signals is directly proportional to the flow velocity.




Specifications

Performance specifications
Velocity range 0.03 ~ ±40ft/s (0.01 ~ ±12m/s)
Accuracy ±0.5%
Pipe size 1’’~200’’ (25mm~5000mm)
Repeatability 0.15% of measured value
Linerarity ±1.0%
Fluid Water, Sea water, Oil, Alcohol...
Pipe material PVC, stainless steel, carbon steel, copper...
Function specifications
Communication & Outputs Communication: ModBus RS485
Analog output: 4~20mA, max load 750Ω.
Pulse output: 0~9999Hz, OCT, (min. and max. frequency is adjustable)
Relay output: max 1Hz(1A@125V AC or 2A@30V DC)
Flow Unit Cubic Meters(m³), Liters(l), USA Gallons(gal). The factory default unit is m3/h.
Time Unit /Day/Hour, /Min, /Sec.
SD Card Max record: 2GB, working more than 1000 days

Storage time interval: 1~86400s
Power supply 24V DC/1A@ max
Keypad 16 touch keys
Display 20×2 lattice alphanumeric, back lit LCD.
Temperature Transmitter: -40℉~140℉ (-40℃~60℃)
Transducer: -40℉~248℉ (-40℃~120℃)
Humidity Up to 99% RH, non-condensing
Physical specifications
Transmitter Die-cast aluminum, IP65, CNC machined
Transducer Encapsulated design, protection grade IP68
Transducer cable Standard cable length: 33ft (10m).
Weight Transmitter: 1kg




Product Dimension


Transmitter
ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 1
Normal transducer
ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 2
High-temperature transducer
ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 3
Ultra High-temperature transducer
ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 4



Product Display

ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 5





Communication and Output Functions

ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 6


The ST502 Fixed Ultrasonic Flow Meter is equipped with multiple communication and output options to ensure seamless integration into various industrial control systems. These outputs enable real-time data acquisition, remote monitoring, and control of flow-related processes.

ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 7



Summary of Output Capabilities

Output Type Function Application Examples
RS485(Modbus) Digital communication Remote monitoring, SCADA, system integration
4-20mA

Analog input

Analog output

PLC input, process feedback, DCS systems
OCT Pulse Flow totalization output Batch controllers, energy meters, flow loggers
Relay Alarm/control output Trigger alarmscontrol valves/pumps, flow safety protection



Wiring Diagram

ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 8




Installation Methods


The V method is considered as the standard method. It usually gives a more accurate reading and is used on pipe diameters ranging from 25mm to 400mm (1~16”)approximately. Also,it is convenient to use, but still requires proper installation of the transducer, contact on the pipe at the pipe's centerline and equal spacing on either side of the centerline. ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 9
The signal transmitted in a Z method installation has less attenuation than a signal transmitted with the V method. This is because the Z method utilizes a directly transmitted (rather than reflected) signal which transverses the liquid only once.
The Z method is able to measure on pipe diameters ranging from 100mm to 3000mm(4”~120”).
ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 10
With the N method, the sound waves traverse the fluid twice and bounce three times off the pipe walls. It is suitable for small pipe diameter measurement. The measurement accuracy can be improved by extending the transit distance with the N method
(uncommonly used).
ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 11
As with the N method, the measurement accuracy can also be improved by extending the transit distance with the W method. The sound wave traverses the fluid four times and bounces four times off the pipe walls. It is suitable for very small pipe(diameters less than 50mm,2"). ST502 Water Treatment System applying ultrasonic flowmeter technology with transit time methods for and accurate liquid flow monitoring 12