logo
products
products
Home > products > Ultrasonic Energy Meter > ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply

ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply

Product Details

Place of Origin: ShenZhen

Brand Name: Flo-Instru

Certification: CE; ISO9001

Model Number: ST505

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Conventional Packaging

Delivery Time: 3-5 working days

Payment Terms: T/T

Get Best Price
Highlight:

1A max Stationary Ultrasonic Energy Meter

,

Accurate Stationary Ultrasonic Energy Meter

,

24V DC Stationary Ultrasonic Energy Meter

Velocity Range:
0 ~ ±16ft/s (0 ~ ±5m/s)
Accuracy:
±1.0%
Pipe Size:
1”~48”(25mm~1200mm)
Fluid:
Water, Sea Water, Oil, Alcohol...
Pipe Material:
PVC, Carbon Steel, Stainless Steel...
Optional Outputs:
OCT Pulse Output: 0~5000Hz. Analog Output: 4~20mA, Max Load 750Ω.
Communication Interface:
RS485
Power Supply:
24V DC/1A@max
Keypad:
16(4×4) Key With Tactile Action
Display:
20×2 Lattice Alphanumeric, Back Lit LCD.
Temperature:
Transmitter: -40℉~140℉ (-40℃~60℃); Transducer: 32℉~140℉ (0℃~60℃)
Humidity:
Up To 99% RH, Non-condensing
Transmitter:
Aluminum Alloy, IP65.
Transducer:
Encapsulated Design, IP68.
Transducer Cable:
Standard Cable Length: 33ft (10m).
Velocity Range:
0 ~ ±16ft/s (0 ~ ±5m/s)
Accuracy:
±1.0%
Pipe Size:
1”~48”(25mm~1200mm)
Fluid:
Water, Sea Water, Oil, Alcohol...
Pipe Material:
PVC, Carbon Steel, Stainless Steel...
Optional Outputs:
OCT Pulse Output: 0~5000Hz. Analog Output: 4~20mA, Max Load 750Ω.
Communication Interface:
RS485
Power Supply:
24V DC/1A@max
Keypad:
16(4×4) Key With Tactile Action
Display:
20×2 Lattice Alphanumeric, Back Lit LCD.
Temperature:
Transmitter: -40℉~140℉ (-40℃~60℃); Transducer: 32℉~140℉ (0℃~60℃)
Humidity:
Up To 99% RH, Non-condensing
Transmitter:
Aluminum Alloy, IP65.
Transducer:
Encapsulated Design, IP68.
Transducer Cable:
Standard Cable Length: 33ft (10m).
ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply

ST505 Stationary Ultrasonic Energy Meter

Integrate into your management system to provide remote measurement services.

 

Product Information

 

ST505 is a high-accuracy ultrasonic energy meter with clamp-on transducers measuring big pipe diameter, which is built-in RTD module. When it is equipped with PT100 temperature sensor, ST505 can be upgraded into energy meter used for measuring individual energy consumption in any liquid heating/cooling systems. The meter is supplied complete with flowmeter and temperature sensor, which can makes the system real-time detect the temperature of supply and return pipe.

 

The energy meter can be widely applied in various applications, like HVAC, cooling tower, data center, energy audit, and building(shipping mall, office, museum, hospital, school, subway etc.). Energy meter, also called thermal energy meter or heat meter, is used to accurately measure heat consumption in heating and cooling facilities so as to reach energy-saving and cost-saving.

 

ST505 is a brand-new high-end product that is made of aluminum alloy material and realizes CNC processing method. It adopts the industry-leading full-sealed iron-absorbing side-opening technology without any screw locking, and the tedious steps of screwing are reduced. Such a convenient design truly realizes "one-second opening".

 

 

Benefits

  • Measure the actual flow and total consumption of various liquids.
  • No loss of process control, optimization of assets and efficiency, no downtime or expense from calibration.
  • Adaptive signal processing algorithms optimize performance, ensuring accurate measurements even in challenging flow conditions.
  • Clear display interface and LCD display with alarm function, easy to operate and debug
  • Utilize transit-time ultrasonic technology so as to realize bi-directional flow measurement by precisely measuring the time it takes for ultrasonic signals to transmit upstream and downstream.
  • Leverage the data logging capabilities to analyze historical flow patterns to make system optimization.
  • Built-in keypad and simple menu system for fast and easy programming of pipe diameter, pipe material, liquid type, and measurement nuits.

 

 

Product Features

 

Dimension

 

ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply 0
ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply 1
Transmitter

 

ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply 2
Transducer

 

 

Technical Information

 

Parameter

 

Performance Specifications
Velocity Range 0.03~±16ft/s (0.01~±5m/s)
Accuracy ±1% of measured value
Repeatability 0.3% of measured value
Pipe Size 1" ~ 48" (25mm ~ 1200mm)
Power Supply 24V DC
Keypad 16 touch bottons
Display (20×2) ,alphanumeric, backlit LCD.
Function Specifications
Output Analog output: 4~20mA, max load 750Ω.
Pulse output: 0~9999Hz, OCT, (min. and max. frequency is adjustable)
Relay output: max 1Hz(1A@125V AC or 2A@30V DC)
Communication RS485
Liquid water, sea water, oil, alcohol...
Pipe Material PVC, stainless steel, carbon steel, copper...
Physical Specifications
Transmitter Die-cast aluminum, IP65, CNC machined
Transducer Encapsulated design, protection grade IP68
Double-shielded transducer cable
The standard/maximum length of cable: 30ft/1000ft(9m/305m)
Temperature Transmitter: -40℉~140℉(-40℃~60℃)
Transducer: 32℉~140℉(0℃~60℃) Standard
PT100 Temp. Sensor: 32℉~257℉(0℃~125℃)
Humidity Up to 99% RH, non-condensing
 

 

 

Installation

 

V Method

The "V" method is considered as the standard method. It usually gives more accurate reading and is used on pipe diameters ranging from 25mm to 400mm(1'' ~ 16'') approximately. Also, it's convenient to use, but still requires proper installation of the transducer, contact on the pipe at the pipe's centerline and equal spacing on either side of the centerline.

ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply 3

 

Z Method

The signal transmitted in a "Z" method installation has less attenuation than a signal transmitter with the "V" method. This is because the "Z" method utilizes a directly transmitted(rather than reflected) signal which transverses the liquid only once. The "Z" method is able to measure on pipe diameters ranging from 100mm to 3000mm(4”~120”).

ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply 4

 

N Method

With the "N" method, the sound waves transverse the fluid twice and bounce three times off the pipe walls. It's suitable for small pipe diameter measurement. The measurement accuracy can be improved by extending the transit distance with the "N" method(uncommonly used).

ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply 5

 

W Method

As with the "N", the measurement accuracy can also be improved by extending the transit distance with the "W" method. The sound wave transverse the fluid four times and bounces four times off the pipe walls. It's suitable for very small pipe(diameter is less than 50mm/2'').

ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply 6

 

 

Wiring

ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply 7

 

 

 

 

Package & Accessory

ST505 Stationary Ultrasonic Energy Meter Accurate and Measurement with 24V DC/1A max Power Supply 8

 

 

 

Order Information

 

ST505 Code Specification
  F Uitrasonic Flow Meter(Optional)
E Ultrasonic BTU/Energy Meter(Standard)
  Code Transducer
CT039 Clamp-on transducer:
32℉~140℉ (0℃~60℃)(Standard)
IT215 Insertion transducer:
-40F~176F(-40℃~80℃)(Optional)
  Code Cable Length
L Standard cable length:33ft(10m)
L+ On request other lengths
  Code Temperature Sensor
PT100 Temperature:32℉~257℉ (0℃~125℃)
         
ST505 E CT039 L Complete ordering information