logo
Products
Products
Home > Products > Insertion Ultrasonic Flowmeter > ST502 Insertion Ultrasonic Flow Meter with ±0.5% Accuracy for DN25-DN5000 Pipe Size and IP65 Enclosure

ST502 Insertion Ultrasonic Flow Meter with ±0.5% Accuracy for DN25-DN5000 Pipe Size and IP65 Enclosure

Product Details

Place of Origin: Shenzhen

Brand Name: Flo-Instru

Certification: CE; ISO9001

Model Number: ST502

Payment & Shipping Terms

Minimum Order Quantity: 1

Packaging Details: Conventional Packaging

Delivery Time: 3-5 working days

Payment Terms: T/T

Get Best Price
Highlight:
Pipe Size:
DN25-DN5000
Repeatability:
0.15%
Output:
4-20mA, OCT Pulse Output, Relay Output, RS-232 / RS-485, RTD Temp. Input
Power Supply:
24V DC
Velocity Range:
0.03 ~±40ft/s (0.01~±12m/s)
Transducers Temperature:
-40℉ ~ +176℉ (-40℃~+80℃)
Pipe Size:
DN25-DN5000
Repeatability:
0.15%
Output:
4-20mA, OCT Pulse Output, Relay Output, RS-232 / RS-485, RTD Temp. Input
Power Supply:
24V DC
Velocity Range:
0.03 ~±40ft/s (0.01~±12m/s)
Transducers Temperature:
-40℉ ~ +176℉ (-40℃~+80℃)
ST502 Insertion Ultrasonic Flow Meter with ±0.5% Accuracy for DN25-DN5000 Pipe Size and IP65 Enclosure
ST502 Flow Meter for Large Diameter Water Pipelines
ST502 Insertion Type Ultrasonic Flowmeter
Ultrasonic flow meters that use transit-time methods to measure flow.
Introduction
The ST502 Insertion-Type Ultrasonic Flow Meter utilizes advanced digital signal processing technology to achieve ±0.5% high-accuracy flow measurement across a wide range of pipe sizes and clean liquid applications. Designed with a robust industrial-grade insertion probe, the ST502 provides strong ultrasonic coupling directly within the flow stream, ensuring excellent signal strength, long-term stability, and dependable performance.
A clear, intuitive user interface and menu system allow for easy configuration and operation. Unlike clamp-on models, the insertion design positions the ultrasonic transducers directly inside the pipe, enabling stronger signal penetration and enhanced stability—particularly beneficial for large-diameter pipelines, complex process conditions, or applications requiring highly reliable and repeatable measurements.
Engineered for versatility, the ST502 is ideal for water distribution systems, cooling loops, industrial process liquids, energy monitoring, and HVAC applications. Its combination of high accuracy, stable performance, and durable construction makes it a dependable solution for long-term flow monitoring and critical measurement tasks.
Benefits
  • Measures the actual flow and total consumption of various liquids
  • CNC machined process, magnetic open cover technology without any screws
  • Adaptive signal processing algorithms optimize performance, ensuring accurate measurements even in challenging flow conditions
  • Clear display interface and LCD display with alarm function, easy to operate and debug
  • Utilize transit-time ultrasonic technology to realize bidirectional flow measurement by precisely measuring the time it takes for ultrasonic signals to transmit upstream and downstream
  • Built-in 2G SD card and leverage storage capabilities to analyze historical flow data for system optimization
  • Built-in keypad and simple menu system for fast and easy option of pipe diameter, pipe material, liquid type, and measurement units
ST502 is a brand-new high-end product made of aluminum alloy material using CNC processing methods. It adopts industry-leading full-sealed iron-absorbing side-opening technology without any screw locking, reducing tedious steps of screwing. This convenient design truly realizes "one-second opening".
Principle
The Transit-Time (TVT) Ultrasonic Flow Meter is a highly reliable flow measurement technology widely used for clean liquids. Unlike clamp-on designs, the insertion-type meter places the ultrasonic transducers directly into the pipe wall so they make contact with the fluid. This ensures strong ultrasonic transmission, excellent signal quality, and stable long-term performance, especially on large or thick-walled pipes.
In an insertion-type TVT flow meter, two ultrasonic transducers are inserted into the pipe wall. One transducer transmits a pulse downstream (T_down) with the direction of the fluid, while the other transmits upstream (T_up) against the flow. Because the flowing liquid accelerates the downstream signal and slows the upstream signal, the time difference (Δt=T_up - T_down) is proportional to the flow velocity.
Specifications
Performance Specifications
Velocity range 0.03 ~ ±40ft/s (0.01 ~ ±12m/s)
Accuracy ±0.5%
Pipe size 1"~200" (25mm~5000mm)
Repeatability 0.15% of measured value
Linearity ±1.0%
Fluid Water, Sea water, Oil, Alcohol...
Pipe material PVC, stainless steel, carbon steel, copper...
Function Specifications
Communication & Outputs Communication: ModBus RS485
Analog output: 4~20mA, max load 750Ω
Pulse output: 0~9999Hz, OCT (min. and max. frequency adjustable)
Relay output: max 1Hz (1A@125V AC or 2A@30V DC)
Flow Unit Cubic Meters (m³), Liters (l), USA Gallons (gal). Factory default unit is m³/h
Time Unit /Day/Hour, /Min, /Sec
SD Card Max record: 2GB, working more than 1000 days
Storage time interval: 1~86400s
Power supply 24V DC/1A max
Keypad 16 touch keys
Display 20×2 lattice alphanumeric, back lit LCD
Temperature Transmitter: -40℉~140℉ (-40℃~60℃)
Transducer: -40℉~176℉ (-40℃~80℃)
Humidity Up to 99% RH, non-condensing
Physical Specifications
Transmitter Die-cast aluminum, IP65, CNC machined
Transducer Encapsulated design, protection grade IP68
Transducer cable Standard cable length: 33ft (10m)
Weight Transmitter: 1kg
Product Dimension
Transmitter
ST502 Flow Meter Transmitter Dimensions Diagram
Transducer
ST502 Flow Meter Transducer Dimensions Diagram
Product Display
ST502 Flow Meter Product Display and Interface
Communication and Output Functions
ST502 Flow Meter Communication and Output Functions Diagram
The ST502 Fixed Ultrasonic Flow Meter is equipped with multiple communication and output options to ensure seamless integration into various industrial control systems. These outputs enable real-time data acquisition, remote monitoring, and control of flow-related processes.
ST502 Flow Meter Output Connections and Interface
Summary of Output Capabilities
Output Type Function Application Examples
RS485 (Modbus) Digital communication Remote monitoring, SCADA, system integration
4-20mA Analog input/output PLC input, process feedback, DCS systems
OCT Pulse Flow totalization output Batch controllers, energy meters, flow loggers
Relay Alarm/control output Trigger alarms, control valves/pumps, flow safety protection
Wiring Diagram & Installation Methods
ST502 Flow Meter Wiring Diagram and Installation Methods